                  SPN         COMPONENT          FMI                     CONDITION                          CODE
                        Throttle Body Control - Requested  31  Condition Exists                      P1530
                 520305
                          Throttle Angle Not Plausible
                 520306    ECU ADC Fault - No Load  31  Condition Exists                             P1531
                 520307    ECU ADC Fault - Voltage  31  Condition Exists                             P1532
                         Accelerator Sensor Sync Fault -  31  Condition Exists                       P1533
                 520308
                           Sensor Diff Exceeds Limit
                 520309       ECU Fault - ICO     31   Condition Exists                              P1534
                 520311  ECU Fault - Hardware Disruption  31  Condition Exists                       P1537
                                                  3    Voltage Above Normal, Or Shorted To High Source  P1327
                 520331    Knock Sensor Positive Line
                                                  4    Voltage Below Normal, Or Shorted To Low Source  P1328
                                                  3    Voltage Above Normal, Or Shorted To High Source  P132A
                 520332   Knock Sensor Negative Line
                                                  4    Voltage Below Normal, Or Shorted To Low Source  P132B
                                                  3    Voltage Above Normal, Or Shorted To High Source  P0243
                 520341    Wastegate Solenoid Driver  4  Voltage Below Normal, Or Shorted To Low Source  P0246
                                                  5    Current Below Normal Or Open Circuit          P0245
                 520342    Idle Fuel Correction Bank 1  15  Data Valid But Above Normal Operating Range - Least Severe Level  P116C
                                                  15   Data Valid But Above Normal Operating Range - Least Severe Level  P116E
                 520343    Idle Fuel Correction Bank 2
                                                  17   Data Valid But Below Normal Operating Range - Least Severe Level  P116F
                                                  15   Data Valid But Above Normal Operating Range - Least Severe Level  P0170
                 520344  Adaptive Fuel Correction Bank 1
                                                  17   Data Valid But Below Normal Operating Range - Least Severe Level  P1170
                          Internal fault - Chassis Output  31  Condition Exists                      P1618
                 520376
                                Disabled
                         Non Functional Application SW  31  Condition Exists                         C1681
                 520381
                                Installed
                                                  3    Voltage Above Normal, Or Shorted To High Source  P107D
                 520496  Intercooler Pump Driver Circuit  4  Voltage Below Normal, Or Shorted To Low Source  P107C
                                                  5    Current Below Normal Or Open Circuit          P107E
                                                  4    Voltage Below Normal, Or Shorted To Low Source  P1510
                 520498          Stator
                                                  5    Current Below Normal Or Open Circuit          P1511
                                                  2    Data Erratic, Intermittent Or Incorrect       P1140 / P1368
                 520513    Motor Controller Encoder
                                                  31   Condition Exists                              P1141 / P1369
                                                  3    Voltage Above Normal, Or Shorted To High Source  P1142 / P1165
                          Motor Controller Temperature
                 520514                           4    Voltage Below Normal, Or Shorted To Low Source  P1143 / P1166
                                 Sensor
                                                  31   Condition Exists                              P1144 / P1167
                                                  0    Data Valid But Above Normal Operational Range - Most Severe Level  P1145 / P1168
                 520515    Electric Motor Temperature
                                                  4    Voltage Below Normal, Or Shorted To Low Source  P1B0D / P1169
                 520516   Motor Controller Temperature  0  Data Valid But Above Normal Operational Range - Most Severe Level  P1146 / P116A
                                                  3    Voltage Above Normal, Or Shorted To High Source  P1147 / P1184
                                                  6    Current Above Normal Or Grounded Circuit      P1148 / P1185
                 520517       Motor Controller
                                                  12   Bad Intelligent Device Or Component           P1149 / P1186
                                                  19   Received Network Data In Error                P1150 / P1187
                                                  5    Current Below Normal Or Open Circuit          P1151 / P1177
                 520518    Motor Controller Contactor
                                                  6    Current Above Normal Or Grounded Circuit      P1152 / P1178
                 520519  Motor Controller Speed Sensor  31  Condition Exists                         P1153 / P116B
                 520520    BMC CAN Communication  31   Condition Exists                              P0754
                 520522        Display Relay      5    Current Below Normal Or Open Circuit          P3038
                                                  2    Data Erratic, Intermittent Or Incorrect       P153C
                 524067    Drive Mode Select Switch  3  Voltage Above Normal, Or Shorted To High Source  P153A