Page 211 - Manual Oficina XP 1000 14-16
P. 211

FUEL SYSTEM


                    COMPONENT                   CONDITION                           SPN           FMI          P-CODE
                                                Valid But Below Normal
                                                (least severe)                                    18           P17AF
                    ETC Accelerator Position
                    Sensor Outputs 1 & 2        Correlation Fault                   65613          2            P1135
                    Correlation
                                                Valid But Above Normal                             0            P1223
                                                Valid But Below Normal                             1            P1222
                                                Date Erratic or Intermittent                       2            P0221
                    Throttle Position Sensor 2  Voltage Too High                   520198          3            P0223
                                                Voltage Too Low                                    4            P0222
                                                Abnormal Rate of Change                           10            P0220
                                                Out of Calibration                                13            P1220
                                                Driver Circuit Short to B+                         3            P1835         4
                    All Wheel Drive Control Circuit
                    (AWD)                       Driver Circuit Grounded            520207          4            P1834
                                                Driver Circuit Open / Grounded                     5            P1836
                                                Voltage Above Normal                               3            P1614
                    Chassis Relay               Voltage Below Normal               520208          4            P1613
                                                Open Circuit                                       5            P1611
                                                Data Erratic or Intermittent                       2            P0135
                                                Voltage Above Normal or Shorted
                                                to High Source                                     3            P0032
                    Oxygen Sensor Heater 1      Voltage Below Normal or Shorted    520209
                                                to Low Source                                      4            P0031
                                                Current below Normal or Open                       5            P0030
                                                Circuit
                    Steering Over Current Shut  Current Above Normal or            520221          6           C1050
                    Down                        Grounded
                    Steering Excessive Current  Current Above Normal or
                    Error                       Grounded                           520222          6           C1051
                    Steering Torque Partial Failure Condition Exists               520223         31           C1052
                    Steering Torque Full Failure  Condition Exists                 520224         31           C1053
                                                Greater than 120° C (248° F)                       0           C1055
                    EPS Inverter Temperature                                       520225
                                                Greater than 110° C (230° F)                      16           C1054
                    EPS CAN Communications      No RX Message for 2 Seconds                        2           U0100
                    Receive Error               Condition Exists                   520226         31           C1067
                    EPS CAN Communications      No TX Message for 2 Seconds        520227          2            U1100
                    Transmit Error
                                                Root Cause Unknown                                11           C1065
                    Position Encoder Error      Bad Intelligent Device             520228         12
                                                Condition Exists                                  31           C106B
                                                Bad Intelligent Device                            12           C1070
                    EPS Software Error                                             520229
                                                Condition Exists                                  31           C106F
                    IC CAN Communication with   EPS Off Line (EPS DM1 not seen)
                    EPS                                                            520230         31           U0131
                                                EPS: Key On, Engine Off, 5 Minute
                    EPS Power Save Condition                                       520231         31           C1071
                                                Power Save/Timeout
                    Idle Air Control Valve (IAC)
                    M17; IAC Stepper Pin 3      Driver Circuit Short to B+         520268          3            P1519



                   9926816 R06 - 2014-2016 RZR XP 1000 / XP4 1000 Service Manual                                      4.43
                   © Copyright Polaris Industries Inc.