Page 192 - Manual Oficina Polaris RZR XP 1000 17-18
P. 192

ENGINE / COOLING SYSTEM

                VALVE COVER INSTALLATION
                1. Apply anti-seize compound to spark plug threads.

                2. Install spark plugs q and torque to specification.
                3. Prepare valve cover sealing surfaces by cleaning
                   thoroughly to remove all residue.
                4. Install valve cover seal w.
                5. Install the four valve cover shoulder bolts e and new
                   isolators r using a T40 driver.




















                6. Torque valve cover bolts to specification.

                                    TORQUE
                                   Spark Plugs:
                                  7 ft-lbs (10 Nm)

                                 Valve Cover Bolts:
                                  7 ft-lbs (10 Nm)