Page 210 - Manual Oficina Polaris RS1 2018 e 2019
P. 210

FUEL SYSTEM


                1. From the canister filter, route fuel vent line under fuel  VENT LINE TERMINATION FITTING
                   purge and fuel EVAP lines. Secure vent line to the  This fitting should be inspected and tested using a Mity
                   seat bracket support with two hinge clips w.      Vac™ to ensure proper venting. Connect the Mity Vac to
                                                                     the fitting and give it 5 pumps. The gauge should return
                                                                     to 0 immediately or there is an obstruction.


















                2. Route vent line up the lower rocker tube, and secure
                   with two hinge clips w.
                3. Route vent line along outside of the intake and attach
                   the vent line to the fitting e in the frame.                            NOTE
                                                                      If the vent line fitting is removed from the frame, it must
                                                                       be replaced. The ears on the clip (arrows) will not hold
                                                                                  properly once it is removed.

















































                4.24                                                                      9928689 - 2018 RZR RS1 Service Manual
                                                                                                © Copyright Polaris Industries Inc.