ELECTRICAL

                TESTING FOR INTERMITTENT CONDITIONS                  TESTING CURRENT FLOW (AMPERAGE)
                Intermittent conditions are very difficult to diagnose, as  Performing a current flow test requires the meter leads
                when you are testing the circuit, you may not have the  be inserted into the correct cavities in the meter, and be
                circuit failing to indicate where the issue is. Intermittent  placed in series in the circuit to be tested. Refer to your
                electrical failures are almost always related to a poor  Digital Multi Meter’s owner’s manual for potential model
                connection that only goes open in specific situations,  specific instructions. Ensure you are using acceptable
                such as going over a certain kind of bump, at a certain  adapters to avoid damaging the connector terminals.
                temperature, or when the machine is torque loaded in  Connector Probing Guidelines, page 11.7
                one way.
                                                                                           NOTE
                Here is a list of possible failures that can be associated
                with an intermittent electrical failure:                  As there are very infrequently amperage specs
                                                                       provided for circuits/components, please only perform
                • Loose female terminal in an electrical connector.
                                                                              this test when advised in the manual.
                                      NOTE
                 If the terminals in question are the correct size/series,               CAUTION
                  always use PV–43526 to test the drag when inserting  Many circuits on this machine will exceed the 10 Amp
                 and removing the test terminal adapters. Compare the  fuse in most Digital Multi Meters in normal operation.
                    effort to the drag against the known good tester
                               terminal for reference.

                • Poor terminal to wire crimp.
                • Terminal crimp that occurred at least partially on
                  insulation instead of the conductor wire strands.
                • Terminal fretting corrosion
                • Contamination/moisture corrosion
                • A full or partial break of the conductor wires in the
                  insulation, with or without visible insulation damage.
                • Improper routing, especially when it leads to chaffing
                  or heat damage, especially near exhaust.

                You may need to use different techniques to duplicate
                these concerns. These include but are not limited to:
                • Moving the harness by wiggling it or flexing certain
                  areas.
                • Pulling at or near the suspected connector.
                • Pushing in different directions to flex the connector
                  body and try to isolate poor connections.
                • Changing the temperature. This can be accomplished
                  with either heat guns or cold air guns.

                                     WARNING
                  Always exercise caution when using these tools, and
                  use them for short periods of time when changing the
                  temp of an area. Failure to do so can lead to Serious
                        injury and/or damage to the machine.





















                11.10                                                                     9928689 - 2018 RZR RS1 Service Manual