CRANKSHAFT REMOVAL CRANKSHAFT INSPECTION
1. Remove the engine from the engine stand and place
the assembly on a sturdy work bench. NOTE
The connecting rod uses plain bearings. The
2. Install the crankshaft removal / installation tool on to
the PTO side crank case. connecting rod bearings are not serviceable. If ANY
excessive wear or movement is present or if the rod
Crankshaft Removal / Installation Tool does not rotate on the crankshaft freely, the crankshaft
PU-50784 assembly must be replaced.
• Install plate q over adapter w. 1. Use a feeler gauge to measure the connecting rod
• Evenly attach the assembly onto the PTO side big end side clearance q. 3
crankcase using the four bolts as shown below.
• Thread the crankshaft removal screw e into w.
Connecting Rod Big End Side Clearance:
0.00590-.01771″ (.15 - .45mm)
2. Measure the connecting rod small end I.D. w.
3. With the help of an assistant holding the crankshaft,
slowly tighten the screw e until the crankcase is
completely separated from the crankshaft.
Small End I.D. Standard:
4. Remove all special tools from the crankcase.
0.8665 - 0.8670″ (22.010 - 22.023 mm)
Service Limit: 0.08682″ (22.053 mm)
9926813 R06 - 2013-2016 RZR 570 Service Manual 3.75