Page 296 - Manual Oficina XP 1000 14-16
P. 296
TRANSMISSION
29.Install the detent pawl onto the shift shaft and 32.Apply Crankcase Sealant (3-Bond) onto the cover
carefully install the compression spring. and transmission case mating surface.
Crankcase 3 Bond Sealant
PN 2871557
33.Install the sector cover and align the transmission
case dowel with the alignment hole. Install and torque
the bolts to specification.
TORQUE
Sector Gear Cover Bolts:
12 ft-lb (16 Nm)
34.Install the transmission drain plug and torque to
specification.
30.Install a new O-ring on each shift shaft 3^. Apply a TORQUE
small amount of white lithium grease on the O-rings,
shift shafts and component contact surfaces prior to Fill / Drain Plug:
installing the sector cover. 14 ft-lbs (19 Nm)
35.Install the bellcrank onto the shift shaft. Note the key
splined on the bellcrank and shift shaft. Install the nut
and torque to specification.
TORQUE
Bell Crank Nut:
18 ft-lb (24 Nm)
36.Refer to Transmission Installation, page to
complete the repair.
31.Clean the transmission and gear sector cover mating
surfaces thoroughly.
6.28 9926816 R06 - 2014-2016 RZR XP 1000 / XP4 1000 Service Manual
© Copyright Polaris Industries Inc.