Page 51 - Manual Oficina XP 1000 14-16
P. 51
MAINTENANCE
8. Fill recovery bottle to MAX level with recommended 2. Inspect all engine hoses for cracks, deterioration,
coolant or 50/50 or 60/40 mixture of antifreeze and abrasion or leaks. Replace if necessary.
distilled water as required for freeze protection in
your area.
Recommended Coolant:
Polaris 50/50 Extended Life Anti-freeze 2
2880514 (quart)
2880513 (gallon)
9. Reinstall the recovery bottle cap.
10. If coolant was required, start engine and check for
leaks. Make sure radiator fins are clean to prevent
overheating.
COOLING SYSTEM PRESSURE TEST
Refer to Cooling System Specifications, page .
u Bypass Hose
COOLING SYSTEM HOSES
i Water Pump Outlet Hose
1. Inspect all vehicle hoses for cracks, deterioration,
abrasion or leaks. Replace if necessary. o Oil Cooler Inlet Hose
a Oil Cooler Outlet Hose
3. Check tightness and condition of all hose spring
clamps. Replace if necessary.
q Recovery Bottle
w Engine Hoses
e Radiator Hoses
r To Thermostat Housing
t To Water Pump
y To Radiator
9926816 R06 - 2014-2016 RZR XP 1000 / XP4 1000 Service Manual 2.17