8. Lift the cover from the housing and remove the
thermostat.
NOTE
Thermostat has a pop-off relief to allow the bypass
system to operate until thermostat opens.
9. Install a new thermostat with the bleed hole r
positioned closest to the engine.
3
NOTE
Image shown above is with engine removed for clarity.
10. Reverse this procedure for installation. Torque
thermostat cover bolts to specification.
TORQUE
Thermostat Cover Bolts:
7 ft-lb (10 Nm)
11. Be sure to properly fill and bleed cooling system as
outlined in this chapter.
9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual 3.13