Page 121 - Manual Oficina Polaris RZR XP 1000 17-18
P. 121

ENGINE / COOLING SYSTEM


                   8. Lift the cover from the housing and remove the
                       thermostat.
                                         NOTE
                      Thermostat has a pop-off relief to allow the bypass
                          system to operate until thermostat opens.
                   9. Install a new thermostat with the bleed hole r
                       positioned closest to the engine.

                                                                                                                              3


















                                         NOTE
                     Image shown above is with engine removed for clarity.

                   10. Reverse this procedure for installation. Torque
                       thermostat cover bolts to specification.
                                        TORQUE
                                 Thermostat Cover Bolts:
                                      7 ft-lb (10 Nm)

                   11. Be sure to properly fill and bleed cooling system as
                       outlined in this chapter.
































                   9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual                                      3.13