6. Rotate water pump drive tab r so it matches the 11. Install the four coolant hoses u – a that attach to
angle of the drive slot in the engine. the water pump. Be sure orientation and routing are
correct.
3
CAUTION 12. Install the right rear lower shock bolt and new nut.
The water pump drive tab and slot must be aligned Torque mounting bolt to specification.
properly during installation. Severe engine or water TORQUE
pump damage will occur if the tab and slot are not in
alignment during water pump installation. Rear Shock Mounting Bolt:
70 ft-lbs (95 Nm)
7. Maneuver water pump up through the access hole in
the skid plate on the RH side of the vehicle. 13. Install the right rear wheel. Torque wheel nuts to
specification.
8. Slide water pump into engine crankcase.
9. Be sure water pump is fully seated and the drive tab TORQUE
and slot are properly engaged. Wheel Nuts:
10. Install the three water pump mounting bolts t & y 120 ft-lbs (163 Nm)
and torque to specification.
14. Connect the (-) negative battery cable.
15. Fill and bleed cooling system as outlined in this
chapter.
16. Install the hood, engine service panel and seats.
NOTE
Install different bolt lengths as shown.
TORQUE
Water Pump Mounting Bolts:
7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual 3.17
© Copyright Polaris Industries Inc.