                   For a video demonstration, scan the QR code below, or  TESTING FOR A SHORT TO VOLTAGE
                   right click it and select “open in new tab”.          There are three possible short to voltage causes:

                                                                         1. Internal electronic component short.
                                                                         2. Harness chaffing leading to contact of the circuit
                                                                            being diagnosed to one with B + or a different
                                                                            reference voltage.
                                                                         3. Moisture in a connector or component.
                                                                         TESTING PROCEDURE
                                                                         1. Consult the wiring diagram. Determine which circuit
                                                                            you will be testing.
                                                                         2. Ensure that any static voltage checks advised in
                                                                            relation to the DTC or concern you are diagnosing
                                                                            have been performed and are in spec.
                                                                         3. Ensure you have checked continuity of the circuit.
                                                                            Testing Continuity/Resistancepage 11.8
                                                                         4. Ensure you have checked for a short to ground.
                                                                            Testing For A Short To Groundpage 11.8
                                                                         5. Ensure that neither end of the circuit is connected.

                                                                         6. Set your DMM to DC volts.
                                                                         7. Connect one meter lead securely to the battery
                                                                            negative post.
                                                                         8. Connect the other lead to either end of the
                                                                            disconnected circuit. Ensure you are using the correct
                                                                            adapter.Connector Probing Guidelinespage 11.7
                                                                         9. If there is voltage present, the harness is damaged
                                                                            and should be repaired or replaced. You may need to
                                                                            remove the protective tape and tubing to inspect.
                                                                         10.If the DMM reads 0 volts, the concern may be in a
                                                                            component related to the circuit. If so, checking
                                                                            internal continuity of non-electronic components may
                                                                            reveal the concern, but diagnosis at this point may
                                                                            require using known good parts.