6. Remove the four T40 bolts retaining the valve cover. 9. Measure the valve clearance using a feeler gauge.
7. The engine will need to be rotated four times to 10. If the valve clearance is out of specification, see
inspect all eight valve clearances f. Two valves can Chapter 3 – Valve Clearance Adjustmentpage 3.81.
be measured at each camshaft lobe position.
MEASUREMENT
Intake Valve Clearance (cold):
.006 ± .002″ (0.15 ± 0.05 mm)
Exhaust Valve Clearance (cold):
.010 ± .002″ (0.25 ± 0.05 mm)
11. Repeat steps 18-20 until all eight valves have been
inspected.
12. If previously removed, apply anti-seize compound to
the spark plug threads and reinstall the spark plugs.
Torque spark plugs to specification.
TORQUE
Spark Plug Torque:
NOTE
7 ft-lbs (10 Nm)
Remove spark plugs to aid engine rotation.
13. Inspect the valve cover seal and replace if
8. Rotate the drive clutch counter-clockwise until the necessary.
cam lobes g above the valves you are inspecting
are facing up. 14. Install NEW isolators on the valve cover bolts. Install
the valve cover and the four T40 bolts. Torque bolts
to specification.
TORQUE
Valve Cover Bolts:
7 ft-lbs (10 Nm)
15. Install the spark plug wires back into their correct
location.
16. Install the push rivet that retains the heat shield to
the frame cross member.
2.34 9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual