Page 102 - Manual Oficina XP 1000 14-16
P. 102
ENGINE / COOLING SYSTEM
14. Install a NEW mechanical seal into the water pump 20. Install the water pump cover and three retaining bolts
housing using special tool (PU-50564) u. Press the i. Torque bolts in sequence to specification.
new mechanical seal in until it is flush with the water
pump housing.
TORQUE
15. Rotate water pump shaft after seal installation to Water Pump Cover Bolts:
verify free movement. 7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
16. Place impeller onto the water pump shaft.
21. Install two new water pump (O-rings) and lubricate
®
17. Apply Loctite 204 ™ to the threads of the impeller them with fresh engine oil.
bolt. Install washer and impeller bolt and torque to
specification.
TORQUE
Water Pump Impeller Bolt:
7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
18. Clean cover q and housing gasket surfaces w.
19. Install a new water pump cover gasket e.
3.24 9926816 R06 - 2014-2016 RZR XP 1000 / XP4 1000 Service Manual
© Copyright Polaris Industries Inc.