Page 127 - Manual Oficina Polaris RZR XP 1000 17-18
P. 127
ENGINE / COOLING SYSTEM
14. Install a NEW mechanical seal into the water pump 20. Install the water pump cover and three retaining bolts
housing using special tool (PU-50564) u. Press the i. Torque bolts in sequence to specification.
new mechanical seal in until it is flush with the water
pump housing.
3
TORQUE
15. Rotate water pump shaft after seal installation to Water Pump Cover Bolts:
verify free movement. 7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
16. Place impeller onto the water pump shaft.
21. Install two new water pump (O-rings) and lubricate
®
17. Apply Loctite 204 ™ to the threads of the impeller them with fresh engine oil.
bolt. Install washer and impeller bolt and torque to
specification.
TORQUE
Water Pump Impeller Bolt:
7 ft-lb (10 Nm)(Apply Loctite® 204™ to bolt threads)
18. Clean cover q and housing gasket surfaces w.
19. Install a new water pump cover gasket e.
9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual 3.19
© Copyright Polaris Industries Inc.