Page 475 - Manual Oficina Polaris RS1 2018 e 2019
P. 475

ELECTRICAL


                   TEST 1: Resistance Value of Each Stator Leg           8. Example: The alternator current output reading
                   1. Measure the resistance value of each of the three      should be approximately 21 VAC at 1300 RPM
                       stator legs: Y1 to Y2, Y1 to Y3, and Y2 to Y3. Each   between each ‘leg’.
                       test should measure: 0.07 - 0.13 Ω
                                                                                               NOTE
                                           CONNECT         OHMS           If one or more of the stator leg output AC voltage varies
                        TEST                METER        READING           significantly from the specified value, the stator may
                                          LEADS TO:                                      need to be replaced.
                        Battery Charge      Y1 to Y2    0.07 - 0.13 Ω
                        Coil
                                                                                                      AC VOLTAGE (VAC)
                                                                                 RPM READING
                        Battery Charge                                                                    READING
                        Coil                Y1 to Y3    0.07 - 0.13 Ω
                                                                                      1300               21 VAC ± 25%
                        Battery Charge
                        Coil                Y2 to Y3    0.07 - 0.13 Ω                 3000               47 VAC ± 25%
                                                                                      5000               79 VAC ± 25%
                                         NOTE
                     If there are any significant variations in ohm readings  STATOR (ALTERNATOR) REPLACEMENT
                    between the three legs it is an indication that one of the
                              stator legs may be weak or failed.         Refer to Chapter 3 – Stator Cover Removal / Inspection,
                                                                         page   procedure to service the stator.
                       TEST 2: Resistance Value of Each Stator Leg to                          NOTE
                       Ground
                                                                             The stator cover can be removed with the engine
                   2. Measure the resistance value of each of the stator                installed in the chassis.
                       legs to ground: Y1 to Ground, Y2 to Ground, Y3 to
                       Ground.                                            Be sure to thoroughly clean the area around the stator
                                                                                        cover prior to removal.
                   3. Each test should measure: Open Line (OL)

                                         CONNECT        OHMS
                        TEST             METER          READING
                                         LEADS TO:
                        Battery Charge   Y1, Y2, or Y3  Open Line
                        Coil             to Ground      (Infinity)


                                         NOTE
                    Any measurement other than Infinity (open) will indicate
                                a failed or shorted stator leg.


                       TEST 3: Measure AC Voltage Output of Each
                       Stator Leg at Charging RPM
                   4. Set the selector dial to measure AC Voltage.
                   5. Start the engine and let it idle.
                   6. While holding the engine at a specified RPM,                                                          11
                       separately measure the voltage across each ‘leg’ of
                       the stator by connecting the meter leads to the wires
                       leading from the alternator (Y1 to Y2, Y1 to Y3, Y2 to
                       Y3).
                   7. Refer to the following table for approximate AC
                       Voltage readings according to RPM. Test each leg at
                       the specified RPM in the table.







                   9928689 - 2018 RZR RS1 Service Manual                                                             11.27
                   © Copyright Polaris Industries Inc.
   470   471   472   473   474   475   476   477   478   479   480