ELECTRICAL

                   BATTERY                                               GENERAL BATTERY INFORMATION

                   BATTERY SPECIFICATIONS                                                     WARNING

                                                                          CALIFORNIA PROPOSITION 65 WARNING:Batteries,
                                        Polaris / Johnson Controls 575
                    Type                                                  battery posts, terminals and related accessories contain
                                        Sealed - Maintenance Free
                                                                          lead and lead compounds, and other chemicals known
                    Voltage             12 Vdc                              to the State of California to cause cancer and birth
                                                                            defects or other reproductive harm. WASH HANDS
                    Nominal Capacity                                                     AFTER HANDLING.
                    @ 10 HR Rate        30 AH
                    CCA                 575
                                                                                              WARNING
                    Nominal Open                                             Battery electrolyte is poisonous. It contains acid!
                    Circuit Voltage     12.8 Vdc or more.
                                                                            Serious burns can result from contact with the skin,
                    Recommended         1.8A @ 5-10 HR or 6.0A @ 1                         eyes, or clothing.
                    Charging Rate       HR
                                                                                             ANTIDOTE:
                                                                                      External: Flush with water.
                                         NOTE
                                                                           Internal: Drink large quantities of water or milk. Follow
                    Never attempt to open the battery. If the seal is broken,  with milk of magnesia, beaten egg, or vegetable oil. Call
                       the battery will be ruined and will fail within a few           a physician immediately.
                                         weeks.                            Eyes: Flush with water for 15 minutes and get prompt
                                                                                          medical attention.

                                                                          Batteries produce explosive gases. Keep sparks, flame,
                                                                          cigarettes, etc. away. Ventilate when charging or using
                                                                          in closed space. Always shield eyes when working near
                                                                                              batteries.

                                                                                     Keep out of reach of children.

                                                                         1. Check battery voltage with a volt/ohm meter. A fully
                                                                             charged battery should be 12.8 V or higher.
                                                                         2. If the voltage is below 12.6 V, the battery will need to
                                                                             be recharged (see Chapter 11 – Charging Procedure
                                                                             , page 11.31).
                                                                             To service a Maintenance Free battery:
                                                                         3. Remove battery from the vehicle (see Battery
                                                                             Removal, page  ).
                                                                         4. Test battery with a voltage meter or load tester to
                                                                             determine battery condition. This will determine the
                                                                             length of time required to charge the battery to full
                                                                             capacity. Refer to OCV table (see OCV - Open
                                                                             Circuit Voltage Test, page 11.30).
                                                                         5. Charge the battery as recommended (see –        11
                                                                             Charging Procedure , page 11.31).