ELECTRICAL
BATTERY OFF SEASON STORAGE LOAD TEST
Whenever vehicle is not used for a period of three
months or more, remove the battery from the vehicle, CAUTION
ensure that it's fully charged, and store it out of the sun in To prevent shock or component damage, remove spark
a cool, dry place. Check battery voltage each month plug high tension leads and connect securely to engine
during storage and recharge as needed to maintain a full ground before proceeding.
charge.
A battery may indicate a full charge condition in the OCV
NOTICE
test, but still may not have the storage capacity
Battery charge can be maintained by using a Polaris necessary to properly function in the electrical system.
battery tender or by charging once a month to make up For this reason, a battery capacity or load test should be
for self-discharge. Battery tenders can be left conducted whenever poor battery performance is
connected to automatically charge the battery if voltage encountered.
drops below a pre-determined level.
To perform this test, use a load testing device that has an
adjustable load. Apply a load of three times the ampere-
hour rating. At 14 seconds into the test, check battery
BATTERY TESTING voltage. A good 12V battery will have at least 10.5 volts.
If the reading is low, charge the battery and retest.
Whenever a service complaint is related to either the
starting or charging systems, the battery should be
checked first.
BATTERY CONDUCTANCE ANALYZER
The following are two tests which can easily be made on Conductance describes the ability of a battery to conduct
a sealed Maintenance Free battery to determine its current. A conductance tester functions by sending a low
condition: OCV Test and a Load Test. frequency AC signal through the battery and a portion of
the current response is captured, from this output a
conductance measurement is calculated. Conductance
OCV - OPEN CIRCUIT VOLTAGE TEST testing is more accurate than voltage, specific gravity, or
Battery voltage should be checked with a digital load testing.
multitester. Readings of 12.6 volts or less require further Authorized Polaris dealers/distributors are required to
battery testing and charging. See the following chart and use the conductance analyzer when testing 12V Polaris
“Load Test”. batteries.
NOTICE
Maintenance Free batteries should be kept at a high
state of charge during storage. If the battery is stored or
used at a low state of charge, hard crystal sulfation will
form on the plates, reducing the efficiency and service
life of the battery.
Use a volt/ohm meter to test battery voltage.
OPEN CIRCUIT VOLTAGE
STATE OF CHARGE VOLTAGE
100% 12.8 V and up
75% Charged 12.6 V
50% Charged 12.3 V
25% Charged 12.0 V
0% Charged 11.8 V or less
Polaris MDX-610P
PU-50296
12.26 9930583 R01 - 2020-2021 RZR PRO XP / XP 4 Service Manual