MAINTENANCE
2. Place the battery in the battery holder and secure ENGINE / CHASSIS ELECTRICAL GROUND
with hold-down strap. Inspect the ground cable connections. Remove ground
3. Coat the terminals with dielectric grease or terminals and clean if necessary.
petroleum jelly.
1. Located below the start solenoid q, the chassis
4. Connect and tighten the red (positive) cable(s) first. ground connection w can be accessed through the
left rear wheel area.
5. Connect and tighten the black (negative) cable (s)
last. Torque terminal fasteners to specification.
2. Inspect the chassis ground terminals. Be sure the
grounds are clean and tight.
TORQUE
Battery Terminal Fasteners:
60 in-lbs (7 Nm)
6. Verify that cables are properly routed and reinstall
the driver’s seat.
2.60 9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual
© Copyright Polaris Industries Inc.