ELECTRICAL
VOLTAGE REGULATOR 4. Remove the two regulator mounting fasteners w and
The regulator / rectifier is located between the front remove the regulator through the grill opening.
fascia and the radiator.
NOTE
If the regulator / rectifier case temperature exceeds
230° F or 110° C, the unit will turn itself off to cool down.
The unit will turn on again after it has cooled down to at
least 212° F or 100° C. If it turns off, verify the cooling
fins are clean, free from mud/debris and that adequate
airflow is present.
REGULATOR REPLACEMENT
1. Disconnect the negative battery terminal.
2. Push the locking tabs down on the front fascia grill
and remove the grill.
5. Install regulator onto the mounting plate. Torque
mounting fasteners to specification.
TORQUE
Regulator Mounting Fasteners:
5 ft-lb (7 Nm)
6. Connect the regulator harness connectors. The
connectors are keyed so each connector will only fit
on one of the regulator connectors.
7. Install the grill. Ensure the bottom tabs and the clips
are locked into the front fascia.
8. Install the battery negative terminal. Torque fastener
to specification.
3. Disconnect both regulator connectors q.
TORQUE
Battery Terminal Fastener:
60 in-lbs (7 Nm)
11
9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual 11.45