Page 516 - Manual Oficina Polaris RZR XP 1000 17-18
P. 516
ELECTRICAL
CHARGING PROCEDURE
If battery voltage is 12.6 Vdc or less, the battery may
need recharging. When using an automatic charger, refer
to the charger manufacturer’s instructions for recharging.
Do not exceed 6 amps when charging the battery.
NOTICE
Charge the battery using an automatic charger that will
not exceed 14.6 Vdc. An automatic charger will signal
when charging is complete.
Allow the battery to stand disconnected for at least 1-2
hours after being properly charged. If the voltage drops
below 12.6 volts, charging was ineffective or the battery
needs to be replaced.
WARNING
An overheated battery could explode, causing severe
injury or death. Always watch charging times carefully.
Stop charging if the battery becomes very warm to the
touch. Allow it to cool before resuming charging.
STATE OF VOLTAGE ACTION CHARG-
CHARGE (DC) E TIME
None, check
12.8 or None
100% again in 3
more Required
months
75% - May need
100% 12.6 - 12.8 slight charge 3 - 6 hrs
Needs
50% - 75% 12.3 - 12.6 5 - 11 hrs
Charge
Needs At least
25% - 50% 12.0 - 12.3
Charge 13 hrs
Needs At least
0% - 25% 12.0 or less
Charge 20 hrs
NOTICE
Follow the charger instructions supplied by the
manufacture regarding the order or connections, switch
positions and when to connect the charger to an outlet.
11.48 9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual