ELECTRICAL

                   BATTERY OFF SEASON STORAGE                            LOAD TEST
                   Whenever vehicle is not used for a period of three
                   months or more, remove the battery from the vehicle,                      CAUTION
                   ensure that it's fully charged, and store it out of the sun in  To prevent shock or component damage, remove spark
                   a cool, dry place. Check battery voltage each month    plug high tension leads and connect securely to engine
                   during storage and recharge as needed to maintain a full           ground before proceeding.
                   charge.
                                                                         A battery may indicate a full charge condition in the OCV
                                        NOTICE
                                                                         test, but still may not have the storage capacity
                      Battery charge can be maintained by using a Polaris  necessary to properly function in the electrical system.
                    battery tender or by charging once a month to make up  For this reason, a battery capacity or load test should be
                         for self-discharge. Battery tenders can be left  conducted whenever poor battery performance is
                    connected to automatically charge the battery if voltage  encountered.
                             drops below a pre-determined level.         To perform this test, use a load testing device that has an
                                                                         adjustable load. Apply a load of three times the ampere-
                                                                         hour rating. At 14 seconds into the test, check battery
                   BATTERY TESTING                                       voltage. A good 12V battery will have at least 10.5 volts.
                                                                         If the reading is low, charge the battery and retest.
                   Whenever a service complaint is related to either the
                   starting or charging systems, the battery should be
                   checked first.                                        BATTERY CONDUCTANCE ANALYZER
                   The following are two tests which can easily be made on  Conductance describes the ability of a battery to conduct
                   a sealed Maintenance Free battery to determine its    current. A conductance tester functions by sending a low
                   condition: OCV Test and a Load Test.                  frequency AC signal through the battery and a portion of
                                                                         the current response is captured, from this output a
                                                                         conductance measurement is calculated. Conductance
                   OCV - OPEN CIRCUIT VOLTAGE TEST
                                                                         testing is more accurate than voltage, specific gravity, or
                   Battery voltage should be checked with a digital      load testing.
                   multitester. Readings of 12.6 volts or less require further  Authorized Polaris dealers/distributors are required to
                   battery testing and charging. See the following chart and  use the conductance analyzer when testing 12V Polaris
                   “Load Test”.
                                                                         batteries.
                                        NOTICE
                      Maintenance Free batteries should be kept at a high
                    state of charge during storage. If the battery is stored or
                     used at a low state of charge, hard crystal sulfation will
                     form on the plates, reducing the efficiency and service
                                     life of the battery.
                         Use a volt/ohm meter to test battery voltage.


                              OPEN CIRCUIT VOLTAGE
                       STATE OF CHARGE              VOLTAGE

                             100%                  12.8 V and up
                          75% Charged                 12.6 V
                                                                                                                            11
                          50% Charged                 12.3 V

                          25% Charged                 12.0 V
                          0% Charged               11.8 V or less
                                                                                          Polaris MDX-610P
                                                                                              PU-50296








                   9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual                                     11.47