ELECTRICAL

                BATTERY

                BATTERY SPECIFICATIONS                               GENERAL BATTERY INFORMATION

                                    Polaris / Johnson Controls 575
                 Type                                                                      WARNING
                                    Sealed - Maintenance Free
                                                                      CALIFORNIA PROPOSITION 65 WARNING:Batteries,
                 Voltage            12 Vdc                            battery posts, terminals and related accessories contain
                                                                       lead and lead compounds, and other chemicals known
                 Nominal Capacity                                        to the State of California to cause cancer and birth
                 @ 10 HR Rate       30 AH
                                                                        defects or other reproductive harm. WASH HANDS
                 CCA                575                                              AFTER HANDLING.
                 Nominal Open
                 Circuit Voltage    12.8 Vdc or more.                                      WARNING

                 Recommended        1.8A @ 5-10 HR or 6.0A @ 1           Battery electrolyte is poisonous. It contains acid!
                 Charging Rate      HR                                  Serious burns can result from contact with the skin,
                                                                                       eyes, or clothing.
                                     NOTICE
                                                                                         ANTIDOTE:
                 Never attempt to open the battery. If the seal is broken,         External: Flush with water.
                    the battery will be ruined and will fail within a few  Internal: Drink large quantities of water or milk. Follow
                                      weeks.                          with milk of magnesia, beaten egg, or vegetable oil. Call
                                                                                    a physician immediately.
                                                                       Eyes: Flush with water for 15 minutes and get prompt
                                                                                       medical attention.

                                                                      Batteries produce explosive gases. Keep sparks, flame,
                                                                       cigarettes, etc. away. Ventilate when charging or using
                                                                      in closed space. Always shield eyes when working near
                                                                                          batteries.

                                                                                  Keep out of reach of children.

                                                                     1. Check battery voltage with a volt/ohm meter. A fully
                                                                         charged battery should be 12.8 V or higher.
                                                                     2. If the voltage is below 12.6 V, the battery will need to
                                                                         be recharged (see Chapter 11 – Charging Procedure
                                                                         page 11.48).
                                                                         To service a Maintenance Free battery:
                                                                     3. Remove battery from the vehicle (see Battery
                                                                         Removalpage 2.59).
                                                                     4. Test battery with a voltage meter or load tester to
                                                                         determine battery condition. This will determine the
                                                                         length of time required to charge the battery to full
                                                                         capacity. Refer to OCV table (see OCV - Open
                                                                         Circuit Voltage Testpage 11.47).
                                                                     5. Charge the battery as recommended (see –
                                                                         Charging Procedure page 11.48).

                                                                     BATTERY REMOVAL / INSTALLATION
                                                                     See Chapter 2 – Battery Removalpage 2.59 and Battery
                                                                     Installationpage 2.59 procedures.








                11.46                                                  9928492 R06 - 2017-2018 RZR XP 1000 / XP4 1000 Service Manual
                                                                                                © Copyright Polaris Industries Inc.