Page 700 - Manual Oficina Polaris Sportsman 570 2014 a 2016
P. 700

ELECTRICAL

                STATOR OUTPUT TEST                                   2. Measure the resistance value of each of the stator
                Three tests can be performed using a multimeter to       legs to ground: Y1 to Ground, Y2 to Ground, Y3 to
                determine the condition of the stator (alternator).      Ground.
                                                                                           NOTE
                                                                      Any measurement other than Infinity (open) will indicate
                                                                                  a failed or shorted stator leg.

                                                                         TEST 3: Measure AC Voltage Output of Each
                                                                         Stator Leg at Charging RPM
                                                                     3. Set the selector dial to measure AC Voltage.
                                                                     4. Start the engine and let it idle.
                                                                     5. While holding the ATV at a specified RPM,
                                                                         separately measure the voltage across each “leg” of
                                                                         the stator by connecting the meter leads to the wires
                                                                         leading from the alternator (Y1 to Y2, Y1 to Y3, Y2 to
                                                                         Y3).
                                                                     6. Refer to the table below for approximate Voltage AC
                                                                         readings according to RPM. Test each leg at the
                TEST 1: Resistance Value of Each Stator Leg
                                                                         specified RPM in the table.
                1. Measure the resistance value of each of the three
                   stator legs: Y1 to Y2, Y1 to Y3, and Y2 to Y3. Each    RPM READING           AC VOLTAGE
                   should measure 0.19 ohms ± 15 %.                                             (VAC) READING
                               CONNECT                                    1300                  22 VAC ± 25%
                    TEST       METER WIRES        READING IN              3000                  51 VAC ± 25%
                               TO:                OHMS
                                                                          5000                  85 VAC ± 25%
                    Charge     Y1 to Y2           Less than 1 Ω
                    Coil
                                                                                           NOTE
                    Charge     Y1 to Y3
                    Coil                          Less than 1 Ω       If one or more of the stator leg output AC voltage varies
                                                                        significantly from the specified value, the stator may
                    Charge                                                           need to be replaced.
                    Coil       Y2 to Y3           Less than 1 Ω

                    Charge     Y1, Y2, or Y3 to   Open (Infinity)
                    Coil       Ground

                                      NOTE
                 If there are any significant variations in ohm's readings
                between the three legs; it is an indication that one of the
                        three stator legs maybe weak or failed.


                   TEST 2: Resistance Value of Stator Leg to
                   Ground


















                11.38                                           9926803 R06 - 2014-2016 Sportsman 325 / ETX / 450 HO / 570 Service Manual
                                                                                                © Copyright Polaris Industries Inc.